Chat with us, powered by LiveChat

Secure Checkout
Sterile MicroPlus -21 STL Membrane, w/ 3.1mm White Grid for Membrane-Butler, 0.45um, 50mm

Thumbnail Filmstrip of Sterile MicroPlus -21 STL Membrane, w/ 3.1mm White Grid for Membrane-Butler, 0.45um, 50mm Images

    Purchase Sterile MicroPlus -21 STL Membrane, w/ 3.1mm White Grid for Membrane-Butler, 0.45um, 50mm

    Sterile MicroPlus -21 STL Membrane, w/ 3.1mm White Grid for Membrane-Butler, 0.45um, 50mm SKU: 10407734

    $203.99 $216.00
    Save $12.01
    Ships in 10 business days
     

    Cellulose Nitrate (CN) Membrane Filters - 10407734

    The Whatman 10407734 combines a controlled pore size distribution with low extractable levels, ensuring the data accuracy that sensitive analytical methods require. Designed for laboratory performance, verified 0.45 pore distribution across the Hydrophilic membrane surface guarantees batch-to-batch consistency in particle capture and analyte passage. Lot-level verification of pore size, flow rate, and physical dimensions ensures that membrane performance remains predictable when scaling from method development to routine analysis.

    Material Specifications

    • Dissolves completely in specific organic solvents, enabling full recovery of captured particles from the membrane surface for downstream gravimetric, chemical, or spectroscopic analysis.
    • Surface retention characteristics allow captured particles and microorganisms to remain on the membrane face, supporting direct microscopic examination and physical recovery of collected material.
    • Validated Gamma sterilization process delivers documented SAL (Sterility Assurance Level) compliance for critical pharmaceutical and biological applications.
    • Cellulose nitrate membranes feature a narrow pore size distribution and low extractable levels, providing the controlled retention characteristics required for gravimetric and particulate analysis.
    • High protein binding capacity makes cellulose nitrate the preferred membrane for Western blotting, dot blotting, and nucleic acid immobilization techniques that rely on efficient surface adsorption.

    Maintaining accreditation under ISO 17025 or similar quality frameworks requires documented traceability at every step — the specification compliance of each membrane lot supports your ongoing audit readiness. Because cellulose nitrate dissolves completely in organic solvents like acetone and amyl acetate, you can recover every captured particle from the membrane surface for downstream gravimetric, spectroscopic, or chemical analysis. Take control of your sample preparation variables and ensure that your data reflects the true nature of your work, rather than the quality of your consumables.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    40.6psi
    Color
    white
    Diameter
    50mm
    Extractables
    low
    Filtration Area
    19.63cm²
    Flow Rate
    60ml (Water)
    Grid (Yes/No)
    Yes
    Material
    Cellulose Nitrate (CN)
    Maximum Operating Pressure
    Holder-dependent
    Maximum Operating Temperature (°C)
    121°C
    Membrane Thickness (µm)
    145um
    Pack Count
    100
    pH Range
    4-8
    Pore Size (µm)
    0.45
    Sterility
    Sterile
    Sterilization
    Supplied Sterile (Single Use)
    Support Material
    None
    Wettability
    Hydrophilic
    • Environmental Compliance - Documented retention characteristics at standard pore ratings support reproducibility in regulated testing programs.
    • Microscopy Examination - Particles remain on the membrane surface for direct visual inspection, supporting identification and classification.
    • Bioburden Monitoring - Surface retention keeps captured organisms accessible for direct incubation and enumeration without transfer steps.
    • Routine Sample Prep - Uniform microporous matrix provides consistent flow rates and reliable particle retention for general aqueous solutions.
    • Aerosol Analysis - Low tare weight and acid digestibility enable chemical characterization of airborne particulates from air sampling.
    • Colony Enumeration - Gridded surface variants facilitate accurate plate counting of captured microorganisms under standard magnification.