Cellulose Nitrate (CN) Membrane Filters - 7184-014
Precision-manufactured Hydrophilic membrane with a verified 0.45 pore structure delivers consistent retention performance across demanding laboratory filtration workflows. Optimized for laboratory use, reproducible separation characteristics define the membrane structure, protecting downstream instruments and preserving sample integrity throughout the filtration process. Because of this, controlled production conditions produce membranes with documented pore size distribution and thickness tolerances, supporting method reproducibility across multiple filter lots.
Material Specifications
- Dissolves completely in specific organic solvents, enabling full recovery of captured particles from the membrane surface for downstream gravimetric, chemical, or spectroscopic analysis.
- High protein binding capacity makes cellulose nitrate the preferred membrane for Western blotting, dot blotting, and nucleic acid immobilization techniques that rely on efficient surface adsorption.
- Surface retention characteristics allow captured particles and microorganisms to remain on the membrane face, supporting direct microscopic examination and physical recovery of collected material.
- Economical bulk packaging supports laboratories with high consumable throughput where individual sterile wrapping is unnecessary.
- Cellulose nitrate membranes feature a narrow pore size distribution and low extractable levels, providing the controlled retention characteristics required for gravimetric and particulate analysis.
Scaling your method from development to routine production requires membrane consistency at every lot — the documented specifications of these membranes provide the reproducibility needed to validate the filtration step once. Cellulose nitrate's dimensional stability through autoclaving at 121°C means your membranes maintain their rated pore structure and physical dimensions from pre-sterilization through final analysis, supporting method reproducibility. Take control of your sample preparation variables and ensure that your data reflects the true nature of your work, rather than the quality of your consumables.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 40.6psi
- Color
- white
- Diameter
- 142mm
- Extractables
- low
- Filtration Area
- 158.37cm²
- Flow Rate
- 60ml (Water)
- Grid (Yes/No)
- No
- Material
- Cellulose Nitrate (CN)
- Maximum Operating Pressure
- Holder-dependent
- Maximum Operating Temperature (°C)
- 80°C
- Membrane Thickness (µm)
- 105–140um
- Pack Count
- 25
- pH Range
- 4-9
- Pore Size (µm)
- 0.45
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 30 mins
- Support Material
- None
- Wettability
- Hydrophilic
- Bioburden Monitoring - Surface retention keeps captured organisms accessible for direct incubation and enumeration without transfer steps.
- Aerosol Analysis - Low tare weight and acid digestibility enable chemical characterization of airborne particulates from air sampling.
- Microscopy Examination - Particles remain on the membrane surface for direct visual inspection, supporting identification and classification.
- Environmental Compliance - Documented retention characteristics at standard pore ratings support reproducibility in regulated testing programs.
- Routine Sample Prep - Uniform microporous matrix provides consistent flow rates and reliable particle retention for general aqueous solutions.
- Water Quality Testing - Narrow pore distribution retains indicator organisms consistently for regulatory compliance in environmental laboratories.